Symptoms and the part to check
| Symptom | Likely part |
|---|---|
| Drips from the showerhead or spout | Cartridge (974-0420, 974-5319 or 974-5299) |
| Temperature swings when water is used elsewhere | Pressure balancer (974-2910) |
| Handle spins or will not turn the valve | Valve stem assembly (971-2500) or handle |
| Not hot enough | Temperature limit stop setting, adjusted at the valve |
The parts
- 974-0420: cartridge for 0X8, JX8, VB8 and JV8 deep casting valves.
- 974-2910: pressure balancer only, for the same valves.
- 971-2500: valve stem assembly only, for the same valves.
- 960-4600: screw cover plate for the 0X8 cartridge.
- 940-2400: acrylic tub and shower handle for 0X8 and 0X9.
Counter tip: Pfister made more than one 0X8 cartridge over the years (974-0420, 974-5319, 974-5299). Pull yours and compare before ordering, or send us a photo.
Replacing the whole valve
If the valve body is damaged, the 0X8 rough-in valve comes in several connection types, such as universal (MIP) and PEX crimp, with or without stops. Match the connection to your pipe. Check our shower valve guide for the basics.
Questions we get
Does the 0X8 cartridge fit a JX8 valve?
The 974-0420 cartridge is listed for 0X8, JX8, VB8 and JV8 deep casting valves. Confirm against the cartridge you pull out.